Compatible Biolight Portable One-Piece 3 Leads Medical ECG Cable

Product Details
Customization: Available
Weight: 0.5kg
Properties: Medical Materials & Accessories
Manufacturer/Factory & Trading Company
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2012-07-06
Management System Certification
ISO 9001, ISO 13485
  • Compatible Biolight Portable One-Piece 3 Leads Medical ECG Cable
  • Compatible Biolight Portable One-Piece 3 Leads Medical ECG Cable
  • Compatible Biolight Portable One-Piece 3 Leads Medical ECG Cable
  • Compatible Biolight Portable One-Piece 3 Leads Medical ECG Cable
  • Compatible Biolight Portable One-Piece 3 Leads Medical ECG Cable
  • Compatible Biolight Portable One-Piece 3 Leads Medical ECG Cable
Find Similar Products

Basic Info.

Model NO.
F1E08A3A12
Usage
Surgical Supplies, Snap Lead Wire
Place of Origin
Guangdong, China (Mainland)
Material
TPU/PVC Optional
Color
Light Gray
Color Code
IEC/Aha Optional
Shipping
DHL/FedEx/UPS/EMS
Warranty
One Year
Operating Temperature
0°c~+40°c
Transport Package
Neutral
Specification
ISO13485
Trademark
F1
Origin
Shenzhen, China
HS Code
90181930
Production Capacity
50000

Product Description

Compatible Biolight Portable One-Piece 3 Leads Medical ECG CableCompatible Biolight Portable One-Piece 3 Leads Medical ECG CableCompatible Biolight Portable One-Piece 3 Leads Medical ECG CableCompatible Biolight Portable One-Piece 3 Leads Medical ECG CableCompatible Biolight Portable One-Piece 3 Leads Medical ECG Cable




Compatibla: Bioght A type

Specifications: Trunk cable connector: Type AMP 6pin plug
Trunk cable material: 26AWG/5C+Shield
Patient leadwire material: 26AWG/1C+shield
Patient end termination: 4.0 clip

1.0 this specification suited for customer's appointed models.
2.0 usage condition(gb9706.1-2007 10.2.1)
2.1 rated temperature: 25º C.
2.2 operation environment: 10º C~40º C.
2.3 storage and transport method: Individual moistureproof package for each
Product, transport under the conditions of ambient temperature.
3.0 construction
3.1 appearance requests:
A) the cable is round and glossy, the color uniformity, the jacket is ok, no
Disrepair, no dirt, no disfigurement, etc.
B) the surface of the connector is glossy, no burr, no obvious machine scar, no
Disfigurement, no modification, no dirt, no metal rust etc.
C) (ec13: 2002 4.1.1.5/iec60601-2-47 6.1aa)clear dot-color and characters, the
Corresponding printing should be correct. (ec13: 2002 4.1.1.5/iec60601-2-47 6.1aa)
D) product labels for use in line with the requirements of ec53-1995 4.1
E)product labels and graphics in line with the engraved die en980-2008 / eu ce
Requirement
F) product cleaning, disinfection and chemical resistance in ine with the requirements
Of ec53-1995 4.3
3.2 size requirements:
To check the size according to the drawing which was issued by the
Engineer. (the important size requirements, please notify it on time)
3.3 packaging requirements:
The packaging in accordance with the requirements of the engineer
Drawin(incase of special packaging requirements, please promptly notify it. )
4.0 technical requirements
4.1 ansi/aami ec53: 1995/(r)2001
Ecg executive standards: Ansi/aami ec53: 1995/(r)2001
Note: Ansi/aami ec53: 1995/(r)2001 standard the not description
General requested by the executive.
4.2 customer special electrical and mechanical performance requirements.
(please check the implementation standards in remarks. )
4.2.1 electrical performance:
A) conduction test: 100conduct ok, no short circuit, no open circuit,
No color difference.
B) (ec53: 1995 4.5.8&gb/t 5095.2-1997)conduct resistance: Dc500v
≤ 2ω . (ec53: 1995 4.5.8&gb/t 5095.2-1997)
C) high voltage test: Wire&wire, wire&shield for 1000v ac ≤ 0.25ma 1min,
Wire&outside for 5000v dc ≤ 0.25ma 1s(ec53: 1995 4.5.1)
D) insulation test: Dc500v ≥ 20mω . (gb/t 5095.2-1997 11.3)
E) product design their own anti-ec53-1995 4.5.4 comply with the requirements.
4.2.2 mechanical properties:
A) the connector&snap should be done with 90 angle swing test. (ec53-1995 4.5.5)
B) main cable the swing test will weigh 500g, swing angle± 90 degree,
10000 times, height 300mm. Swing speed 40 times / min. (ec53-1995 4.5.5)
C) the trunk cable sr weight 15kg with 1 minute. (ec53-1995 4.5.6)
D). Plug life of products in line with the requirements of ec53-1995 4.5.7,
Eia364 reference design at the same time.
E) connector to connect products in line with the impedance requirements of
Ec53-1995 4.5.8.
F) products designed to connect retention ec53-1995 4.5.9 requirements.
5.0 standard
5.1 all the raw materials should comply with rohs standard
5.2 all of the processing of materials, products must meet iso 10993 standards.

Introduction:

We specialize in the design,development,manufacturing of the medical device and 

accessories,include ECG cable,EKG  cable,ECG electrodes,SPO2 sensor,Temperature 

probe,NIBP CUFF,etc.
Compatible Biolight Portable One-Piece 3 Leads Medical ECG CableCompatible Biolight Portable One-Piece 3 Leads Medical ECG CableCompatible Biolight Portable One-Piece 3 Leads Medical ECG CableCompatible Biolight Portable One-Piece 3 Leads Medical ECG CableCompatible Biolight Portable One-Piece 3 Leads Medical ECG Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier