Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor

Product Details
Customization: Available
Classification: Imaging Diagnostic Equipment
Type: ECG
Manufacturer/Factory & Trading Company
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2012-07-06
Management System Certification
ISO 9001, ISO 13485
  • Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
  • Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
  • Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
  • Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
  • Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
  • Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
Find Similar Products

Basic Info.

Model NO.
F1C4585
Specification
ISO13485
Trademark
F1
Origin
Shenzhen, China
HS Code
90181930
Production Capacity
5000

Product Description

Compatible Philips CO2 Sensor Philips ETCO2 SensorCompatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
Compatible Philips CO2 Sensor Philips ETCO2 Sensor Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
Compatible Philips CO2 Sensor Philips ETCO2 Sensor Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
Compatible Philips CO2 Sensor Philips ETCO2 Sensor 
Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
          Compatible Philips CO2 Sensor Philips ETCO2 Sensor 

1.0 The usage range

   This specification suited for customer's appointed models.

2.0 Ambient condition

   2.1 Ambient temperature: +5-- +40

   2.2 Relative humidity:below80%

   2.3 Atmospheric pressure: 86Kpa-106KPa

   2.4 Storage and transport method: individual moistureproof package. Transport conditions is under the 0--+45 temperature.

3.0 Construction

   3.1 Appearance requests:

              a) The cable is round and glossy. the color uniformity. the jacket

                is ok. no Disrepair. no dirt. no disfigurement. etc.

              b) The surface of the connector is glossy. no burr. no obvious machine scar. no disfigurement. no modification. no dirt. no metal rust etc.

              c)Plugs.cable.connections between the sensors should be strong. reliable

   3.2 Size requirements:

Testing the Size according to the drawing.

               (The important size requirements. please notify it on time)

   3.3 Packaging requirements:

              The packaging in accordance with the requirements of the engineer drawing. (In case of special packaging requirements. please promptly notify it.)

4.0 Technical requirements

   4.1Reference to ISO 9919:2005(E)Special requirements of pulse oximetry  GB 9706.1-2007 Medical lectrical equipment - Part 1: General requirements for safety and essential performance

   4.2 Use performance

4.2.1 SpOTest range and precision

       4.2.1.1 SpO2 Test range: Should be 70% -100%

4.2.1.2 SpO2 Test precision:(90%-100%)  2%; (70%-89%)3%          

4.2.2 Pulse Test range and precision

4.2.2.1Pulse Test range: Should be 30bpm -245bpm

       4.2.2.2 Pulse Test precision:  3 bpm

4.3 Mechanical properties:

     4.3.1Insertion and extraction force: 0.3-2 kgf.

4.3.3Vertical pull length:> 10kg. 1 minutes continuously and the jacket is ok.

(Plug side)

5.0 environmental protection requirements:

5.1All the raw materials should comply with ROHS standard

Principle of Operation:
Non-dispersive infrared (NDIR)

Initialization Time:

Capnogram displayed in less than 20 seconds
Reaching full specifications within 2 minutes.
Co2 Measure Range
0 - 150 mmHg
0 - 19.7%
0 - 20kPa

Co2 Measure Resolution
0.1mmHg
Co2 Accuracy:
0 -40 mmHg
41- 70 mmHg
71-100 mmHg
101-150 mmHg
Respiratory Rate:
Range    3 - 150 BPM
Accuracy ±1 breath
Calibration:
No routine user calibration required, The mainstream sensor an airway adapter , zero is required when changing to a different airway adapter
Compensation:
Barometer Pressure 450 - 850 mmHg.
Operator selectable O2 , N2O, He compensation.
Power Requirements:
5.0 VDC ±5%, power consumption less than 1.3W typical

 Temperature / Humidity:
Operating: 0 ºC to 40 ºC, 10 to 90% RH
Storage:  - 40ºC  to 70 C, <90% RH
Data Interface:
Rs232, 19200 baud rate, standard N-8-1. Fully compatible with Respironics Co2 module's communication protocol
Regulatory:

Designed to comply YY0601 and ISO21647.


Introduction:
We specialize in the design,development,manufacturing of the medical device and accessories,include ECG cable,EKG  cable,ECG electrodes,SPO2 sensor,Temperature probe,NIBP CUFF,etc.

Compatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
Compatible Phi-Lips CO2 Sensor Philips Etco2 SensorCompatible Phi-Lips CO2 Sensor Philips Etco2 SensorCompatible Phi-Lips CO2 Sensor Philips Etco2 SensorCompatible Phi-Lips CO2 Sensor Philips Etco2 Sensor
Order Details: 
1. Please let us know the product model you need
2. We will make proforma invoice for you. 
3. Checking and confirm the invoice. 
4. After payment, all goods will be sent to you in 5-7 days as usual. 
5. OEM/ODM is welcomed. 


Payment: 
T/T, Western Union. 

Shipment: 
1. EMS. DHL. UPS. FedEx, TNT. 
2. It will take 3~7days for shipping (depend on country distance). 
3. Any import charges or fees are buyer's responsibility. 
4. We will provide you the tracking number once the goods sent, tracking it until you get the package. 
5. The shipping cost will be on clients' side. 

 
We are  Professional OEM/ODM Medical Cable Manufacturer,please feel free to contact us:
Contact: Angela
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier