Masimo adult soft SpO2 sensor
Compatible with Masimo reusable sensor
Our corporation is specialized in handling the business of sale SpO2 sensor, ECG cable etc. The company has cooperated with many clients both from domestic and overseas, and has obtained consistently high praise from our customers since it was set up.
1.0The usage range
.
This specification suited for customer's appointed models.
2.0 Ambient condition
2.1: +5° ~+40° .
Ambient temperature: +5° ~+40° .
2.2: ≤ 80%.
Relative humidity: ≤ 80%
2.3: 86KPa~106KPa
Atmospheric pressure: 86KPa~106KPa
2.4, 0° ~+45° .
Storage and transport method: Individual moistureproof package, Transport
Conditions is under the 0° ~+45° Temperature.
3.0Construction
3.1: Appearance requests:
A), The cable is round and glossy, the color uniformity, the jacket
Is ok, no Disrepair, no dirt, no disfigurement, etc.
B), , , The surface of the connector is glossy, no burr, no obvious machine
Scar, no disfigurement, no modification, no dirt, no metal rust etc.
C), , , Plugs, cable, connections between the sensors should be strong
3.2: Size requirements:
Testing the Size according to the drawing.
(The important size requirements, please notify it on time)
3.3: Packaging requirements:
The packaging in accordance with the requirements of the engineer
Drawing. (In case of special packaging requirements, please promptly
Notify it. )
4.0Technical requirements
4.1ISO 9919: 2005(E) GB 9706.1-2007:
Reference to ISO 9919: 2005(E)Special requirements of pulse oximetry
GB 9706.1-2007Medical lectrical equipment - Part 1: General requirements for
Safety and essential performance
4.2: Use performance
4.2.1: SpO2 Test range and precision
4.2.1. 1: 70%~100%;
SpO2 Test range: Should be 70% ~ 100%
4.2.1. 2: 70%~100%, ± 2%; 50%~69%, ± 5%
SpO2 Test precision: (70%~100%)± 2%; (50%~69%)± 5%
4.2.2: Pulse Test range and precision
4.2.2.1: 30 bpm ~245bpm;
Pulse Test range: Should be 30bpm ~ 245bpm
4.2.2. 2: ± 3 bpm
Pulse Test precision: ± 3 bpm
4.3: Mechanical properties:
4.3.1: 0.32kgf.
Insertion and extraction force: 0.3~2 kgf.
4.3.2: >10kg,
1. Vertical pull length: > 10kg, 1 minutes continuously and the jacket is ok.
(Plug side)
5.0environmental protection requirements:
5.1ROHS.
All the raw materials should comply with ROHS standard
6.0The accessory
6.1.
Engineering Graphics
6.2.
The proving documents of Samples' Materials.
6.3.
Sample's Testing Repo
Introduction:
We specialize in the design,development,manufacturing of the medical device and
accessories,include ECG cable,EKG cable,ECG electrodes,SPO2 sensor,Temperature
probe,NIBP CUFF,etc.