• Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor
  • Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor
  • Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor

Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor

Classification: Imaging Diagnostic Equipment
Type: ECG
Transport Package: Neutral
Specification: ISO13485
Trademark: F1
Origin: Shenzhen, China
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
F1L1F02110
HS Code
90181930
Production Capacity
50000 ECG Cable

Product Description

Drager Spo2  Spo2 Extension Cable Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor
Drager Spo2  Spo2 Extension Cable Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor
Drager Spo2  Spo2 Extension Cable Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor
Drager Spo2  Spo2 Extension Cable Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor
We specialize in the design,development,manufacturing of the medical device and accessories,include ECG cable,EKG  cable,ECG electrodes,SPO2 sensor,Temperature probe,NIBP CUFF,etc.


Compatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor

 

Since the various of the models, prices will be quoted only upon request.  
Adult over40kg / Index or other finger. compatible models No.: BIC/ Biolight/BIONET/BIOSYS /BRUKER/DATEX/OHMEDA/ DOLPHIN
Adult finger clip / Pediatric finger clip/ Adult silicone soft/ Pediatric silicone/ Neonate silicone wrap/Adult ear clip/ Veterinary SpO2 sensor / Forehead SpO2 sensor. 

1.0 The usage range

   This specification suited for customer's appointed models.

2.0 Ambient condition

   2.1 Ambient temperature: +5-- +40

   2.2 Relative humidity:below80%

   2.3 Atmospheric pressure: 86Kpa-106KPa

   2.4 Storage and transport method: individual moistureproof package. Transport conditions is under the 0--+45 temperature.

3.0 Construction

   3.1 Appearance requests:

              a) The cable is round and glossy. the color uniformity. the jacket

                is ok. no Disrepair. no dirt. no disfigurement. etc.

              b) The surface of the connector is glossy. no burr. no obvious machine scar. no disfigurement. no modification. no dirt. no metal rust etc.

              c)Plugs.cable.connections between the sensors should be strong. reliable

   3.2 Size requirements:

Testing the Size according to the drawing.

               (The important size requirements. please notify it on time)

   3.3 Packaging requirements:

              The packaging in accordance with the requirements of the engineer drawing. (In case of special packaging requirements. please promptly notify it.)

4.0 Technical requirements

   4.1Reference to ISO 9919:2005(E)Special requirements of pulse oximetry  GB 9706.1-2007 Medical lectrical equipment - Part 1: General requirements for safety and essential performance

   4.2 Use performance

4.2.1 SpOTest range and precision

       4.2.1.1 SpO2 Test range: Should be 70% -100%

4.2.1.2 SpO2 Test precision:(90%-100%)  2%; (70%-89%)3%          

4.2.2 Pulse Test range and precision

4.2.2.1Pulse Test range: Should be 30bpm -245bpm

       4.2.2.2 Pulse Test precision:  3 bpm

4.3 Mechanical properties:

     4.3.1Insertion and extraction force: 0.3-2 kgf.

4.3.3Vertical pull length:> 10kg. 1 minutes continuously and the jacket is ok.

(Plug side)

5.0 environmental protection requirements:

5.1All the raw materials should comply with ROHS standard


Compatible Drager 2.4 Meter SpO2 Extension SpO2 SensorCompatible Drager 2.4 Meter SpO2 Extension SpO2 SensorCompatible Drager 2.4 Meter SpO2 Extension SpO2 SensorCompatible Drager 2.4 Meter SpO2 Extension SpO2 Sensor
Order Details: 
1. Please let us know the product model you need
2. We will make proforma invoice for you. 
3. Checking and confirm the invoice. 
4. After payment, all goods will be sent to you in 5-7 days as usual. 
5. OEM/ODM is welcomed. 


Payment: 
T/T, Western Union. 

Shipment: 
1. EMS. DHL. UPS. FedEx, TNT. 
2. It will take 3~7days for shipping (depend on country distance). 
3. Any import charges or fees are buyer's responsibility. 
4. We will provide you the tracking number once the goods sent, tracking it until you get the package. 
5. The shipping cost will be on clients' side. 

 
We are  Professional OEM/ODM Medical Cable Manufacturer,please feel free to contact us:
Contact: Angela
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now